Mechanical components
Figure 1: Mechanical parts
Item
|
Part Description
|
Spare Part Number
|
---|---|---|
1
|
Access panel
|
|
a) Access panel - Top cover for the server - For use with servers with a system I/O board with caged type heat sinks
|
671351-001
|
|
b) Top cover for the server- For use with
servers with a system I/O board with screw down type heat sinks -
Includes DL360p SE Gen8 Label - For use with DL360p SE Gen8 Ivy Bridge
(IVB)
|
743499-001
|
|
2
|
Miscellaneous hardware kit
|
671354-001
|
a) Power supply blank
|
|
|
b) Power cord clip1
|
||
c) Fan module blank
|
||
3
|
Hard drive blank
|
|
Small Form Factor (SFF) hard drive blank, 6.35 cm (2.5 in)
|
670033-001
|
|
Large Form Factor (LFF) hard drive blank, 8.89 cm (3.5 in)1
|
675039-001
|
|
4
|
Processor blank
|
|
a) Blank central processing unit (CPU) blank cover - For use with System I/O board with caged type heat sinks
|
675061-001
|
|
b) Blank central processing unit (CPU) module - For use with DL360p Gen8 System I/O board with screw-down type heat sinks
|
743136-001
|
|
5
|
Power supply airflow baffle - Upright clear
plastic piece that mounts to the chassis directly in front of the two
power supply bays
|
675037-001
|
6
|
Hard drive cage
|
|
a) Hard disk drive (HDD) cage - Front cage with
eight small form factor (SFF) bays - Includes 20-pin cable, 24-pin
cable, and backplane board1,2
|
667868-001
|
|
b) 10-SFF hard drive cage - Front cage with 10 Small Form Factor (SFF) bays - Includes cable and backplane board2
|
692479-001
|
|
c) 4-LFF hard drive cage - Front cage with
four Large Form Factor (LFF) bays - Includes 20-pin cable, 24-pin cable,
and backplane board1,2
|
667869-001
|
|
7
|
Rack mounting hardware kit
1:
|
|
a) Rack mounting rail kit - For 1U server
models with Small Form Factor (SFF) drives - Includes left and right
telescoping ball bearing type slide rails
|
675042-001
|
|
b) Rack mounting rail kit - For 1U server
models with Large Form Factor (LFF) drives - Includes left and right
telescoping ball bearing type slide rails
|
675041-001
|
|
c) Rack mounting rail kit - For 1U server
models - Includes left and right friction type slide rails
(non-telescoping) - Cannot be used with the cable management arm
|
675040-001
|
|
d) Rack mounting easy install kit 1U - For 1U
server models with Small Form Factor (SFF) drives - Includes left and
right friction type slide rails
|
744111-001
|
|
e) Rack mounting easy install kit 1U - For 1U
server models with Large Form Factor (LFF) drives - Includes left and
right friction type slide rails
|
744112-001
|
|
8
|
Cable management arm
1
|
|
a) Cable management arm kit - Guides the power
and interface cables to prevent binding when the server is slid in and
out of the rack - Mounts to the rear of the rack
|
675043-001
|
|
b) Cable management arm, easy install
|
744113-001
|
|
NOTE: 1: Not shown in Figure 1.
2: If a replacement 24-pin SFF cable (Spare part number 667878-001) or 20-pin SFF cable (Spare part number667877-001) is needed, the cables ship with the 8 SFF hard drive cage (Spare part number 667868-001). If areplacement cable is needed for the 10 SFF drive cage, the cable ships with the 10 SFF drive cage (Spare part number692479-001). |
System components
Figure 2: System parts
Item
|
Part Description
|
Spare Part Number
|
---|---|---|
9
|
Hot-plug power supplies:
|
|
460 W ac Common Slot (CS) Gold
hot-plug power supply - Installs in the computer chassis as primary or
redundant supply (92% efficiency) - Requires 100-240 V ac at 50/60 Hz
|
511777-001
|
|
460 W ac Common Slot (CS) Platinum Plus
hot-plug power supply - Installs in computer chassis as primary or
redundant supply (94% efficiency) - Requires 100-240 V ac at 50/60 Hz 1
|
660184-001
|
|
500 W ac Common Slot (CS) 277 V ac
hot-plug power supply - Installs in the computer chassis as primary or
redundant supply (94% efficiency) - Requires 200-277 V ac at 50/60 Hz
|
638549-001
|
|
750 W ac Common Slot (CS) 277 V ac
hot-plug power supply - Installs in the computer chassis as primary or
redundant supply (94% efficiency) - Requires 200-277 V ac at 50/60 Hz
|
674890-001
|
|
750 W ac Common Slot (CS) Titanium
hot-plug power supply - Installs in the computer chassis as primary or
redundant supply (96% efficiency) - Requires 200-240 V ac at 50/60 Hz
|
700287-001
|
|
750 W ac Common Slot (CS) Gold
hot-plug power supply - Installs in the computer chassis as primary or
redundant supply (92% efficiency) - Requires 100-240 V ac at 50/60 Hz1
|
511778-001
|
|
750 W ac Common Slot (CS) Platinum Plus
hot-plug power supply - Installs in computer chassis as primary or
redundant supply (94% efficiency) - Requires 100-240 V ac at 50/60 Hz1
|
660183-001
|
|
750 W dc Common Slot (CS) Gold
hot-plug power supply - Installs in the computer chassis as primary or
redundant supply (92% efficiency), supports HPE power discovery services1
|
639173-001
|
|
1200 W ac Common Slot (CS) Platinum Plus
hot-plug power supply - Installs in computer chassis as primary or
redundant supply (94% efficiency) - Requires 100-240 V ac at 50/60 Hz -1
|
660185-001
|
|
10
|
HP FlexibleLOM for racks:
|
|
FlexibleLOM Ethernet 1Gb 4-port 331FLR adapter -
Has four 10/100/1000BASE-T RJ45 ports - Requires one x4 (Gen 2) PCI
Express slot (mechanically compatible with x8 and x16 PCI Express slots)
|
789897-001
|
|
Ethernet 10Gb 2-port 530FLR (FlexibleLOM form
factor) adapter - Has two Small Form-factor Pluggable Plus (SFP+) ports
and 256MB integrated buffer memory - For ProLiant Gen8 rack servers1
|
649869-001
|
|
FlexFabric 10Gb 2-port 554FLR (FlexibleLOM form
factor) adapter - Has two Small Form-factor Pluggable Plus (SFP+) ports
and 128MB integrated buffer memory - For ProLiant Gen8 rack servers
|
634026-001
|
|
Band FDR/Ethernet 10/40Gb dual port 544FLR
(FlexibleLOM form factor) adapter - Has two Quad Small Form-factor
Pluggable Plus (QSFP) ports - For ProLiant Gen8 rack servers
|
656090-001
|
|
InfiniBand QDR/Ethernet 10Gb dual port 544FLR
(FlexibleLOM form factor) adapter - Has two Quad Small Form-factor
Pluggable Plus (QSFP) ports - For ProLiant Gen8 rack servers
|
656091-001
|
|
11
|
PCI riser cage - T-shaped metal structure that
mounts towards the rear of the server - Can horizontally mount one full
height x16 PCIe card on one side and one low profile x8 PCIe card on the
other
|
671352-001
|
PCI riser cage - L-shaped metal structure
NOTE: For the DL360p SE Gen 8 ONLY
|
717426-001
|
|
12
|
Heatsink:
|
|
Latch type heatsink - For standard processors
(E5-2600 series less than 135 W power and no E5-2600 v2 series
processors) - Includes thermal grease
|
667880-001
|
|
Latch type heatsink - For high-end processors
(E5-2600 series greater than or equal to 135 W power and all E5-2600 v2
series processors) - Includes thermal grease1
|
667881-001
|
|
Screw down type heatsink - For standard
processors (E5-2600 series less than 135 W power and no E5-2600 v2
series processors) - Includes thermal grease1
|
735506-001
|
|
Screw down type heatsink - For high-end
processors (E5-2600 series greater than or equal to 135 W power and all
E5-2600 v2 series processors) - Includes thermal grease1
|
735507-001
|
|
13
|
Processor:
|
|
Intel Xeon E5-2603 Quad-Core 64-bit processor -
1.80 GHz (Sandy Bridge-EP, 10MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 6.4 GT/s, 80 W thermal design power (TDP),
FCLGA 2011-pin socket)2
3
|
670533-001
|
|
Intel Xeon E5-2603 v2 Quad-Core 64-bit
processor - 1.80 GHz (Ivy Bridge-EP, 10MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 6.4 GT/s, 80 W thermal design power (TDP),
socket FCLGA 2011)1
|
730243-001
|
|
Intel Xeon E5-2609 Quad-Core 64-bit processor
- 2.50 GHz (Sandy Bridge-EP, 10MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 6.4 GT/s, 80 W thermal design power (TDP),
FCLGA 2011-pin socket)1
2,
3
|
670530-001
|
|
Intel Xeon E5-2609 v2 Quad-Core 64-bit
processor - 2.50 GHz (Ivy Bridge-EP, 10MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 6.4 GT/s, 80 W thermal design power (TDP),
socket FCLGA 2011)1
|
730242-001
|
|
Intel Xeon E5-2620 Six-Core 64-bit processor -
2.00 GHz (Sandy Bridge-EP, 15MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 7.2 GT/s, 95 W thermal design power (TDP),
FCLGA 2011-pin socket)1
2,
3
|
670529-001
|
|
Intel Xeon E5-2620 v2 Six-Core 64-bit
processor - 2.10 GHz (Ivy Bridge-EP, 15MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 7.2 GT/s, 80 W thermal design power (TDP),
socket FCLGA 2011)1
|
730241-001
|
|
Intel Xeon E5-2630L Six-Core 64-bit low-power
processor - 2.00 GHz (Sandy Bridge-EP, 15MB Level-3 cache, Intel
QuickPath interconnect (QPI) speed 8.0 GT/s, 60 W thermal design power
(TDP), FCLGA 2011-pin socket)1
2,
3
|
670535-001
|
|
Intel Xeon E5-2630L v2 Six-Core 64-bit
low-power processor - 2.40 GHz (Ivy Bridge-EP, 15MB Level-3 cache, Intel
QuickPath interconnect (QPI) speed 7.2 GT/s, 60 W thermal design power
(TDP), socket FCLGA 2011)1
|
730244-001
|
|
Intel Xeon E5-2630 Six-Core 64-bit processor -
2.30 GHz (Sandy Bridge-EP, 15MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 7.2 GT/s, 95 W thermal design power (TDP),
FCLGA 2011-pin socket)1
2,
3
|
670528-001
|
|
Intel Xeon E5-2630 v2 Six-Core 64-bit
processor - 2.60 GHz (Ivy Bridge-EP, 15MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 7.2 GT/s, 80 W thermal design power (TDP),
socket FCLGA 2011)1
|
730240-001
|
|
Intel Xeon E5-2637 Dual-Core 64-bit processor
- 3.00 GHz (Sandy Bridge-EP, 5MB Level-3 cache, Intel QuickPath
Interconnect (QPI) speed 8.0 GT/s, 80 W thermal design power (TDP),
FCLGA 2011-pin socket)1
2,
3
|
670539-001
|
|
Intel Xeon E5-2637 v2 Quad-Core 64-bit
processor - 3.5 GHz (Ivy Bridge-EP, 15MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 130 W thermal design power (TDP),
socket FCLGA 2011)1
|
730249-001
|
|
Intel Xeon E5-2640 Six-Core 64-bit processor -
2.50 GHz (Sandy Bridge-EP, 15MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 7.2 GT/s, 95 W thermal design power (TDP),
FCLGA 2011-pin socket)1
2,
3
|
670527-001
|
|
Intel Xeon E5-2640 v2 Eight-Core 64-bit
processor - 2.00 GHz (Ivy Bridge-EP, 20MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 7.2 GT/s, 95 W thermal design power (TDP),
socket FCLGA 2011)1
|
730239-001
|
|
Intel Xeon E5-2643 Quad-Core 64-bit processor
- 3.30 GHz (Sandy Bridge-EP, 10MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 130 W thermal design power (TDP),
socket FCLGA 2011)1
2,
3
|
670538-001
|
|
Intel Xeon E5-2643 v2 Six-Core 64-bit processor
- 3.50 GHz (Ivy Bridge-EP, 25MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 130 W thermal design power (TDP),
socket FCLGA 2011)1
|
730248-001
|
|
Intel Xeon E5-2650L Eight-Core 64-bit low-power
processor - 1.80 GHz (Sandy Bridge-EP, 20MB Level-3 cache, Intel
QuickPath interconnect (QPI) speed 8.0 GT/s, 70 W thermal design power
(TDP), FCLGA 2011-pin socket)1
2,
3
|
670534-001
|
|
Intel Xeon E5-2650L v2 Ten-Core 64-bit
low-power processor - 1.70 GHz (Ivy Bridge-EP, 25MB Level-3 cache, Intel
QuickPath interconnect (QPI) speed 8.0 GT/s, 70 W thermal design power
(TDP), socket FCLGA 2011)1
|
730250-001
|
|
Intel Xeon E5-2650 Eight-Core 64-bit
processor - 2.00 GHz (Sandy Bridge-EP, 20MB Level-3 cache, Intel
QuickPath interconnect (QPI) speed 8.0 GT/s, 95 W thermal design power
(TDP), FCLGA 2011-pin socket)1
2,
3
|
670526-001
|
|
Intel Xeon E5-2650 v2 Eight-Core 64-bit
processor - 2.60 GHz (Ivy Bridge-EP, 20MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 95 W thermal design power (TDP),
socket FCLGA 2011)1
|
730238-001
|
|
Intel Xeon E5-2660 Eight-Core 64-bit
processor - 2.20 GHz (Sandy Bridge-EP, 20MB Level-3 cache, Intel
QuickPath interconnect (QPI) speed 8.0 GT/s, 95 W thermal design power
(TDP), FCLGA 2011-pin socket)1
2,
3
|
670525-001
|
|
Intel Xeon E5-2660 v2 Ten-Core 64-bit processor
- 2.20 GHz (Ivy Bridge-EP, 25MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 95 W thermal design power (TDP),
socket FCLGA 2011)1
|
730237-001
|
|
Intel Xeon E5-2665 Eight-Core 64-bit
processor - 2.40 GHz (Sandy Bridge-EP, 20MB Level-3 cache, Intel
QuickPath interconnect (QPI) speed 8.0 GT/s, 115 W thermal design power
(TDP), FCLGA 2011-pin socket)1
2,
3
|
670524-001
|
|
Intel Xeon E5-2667 Six-Core 64-bit processor -
2.90 GHz (Sandy Bridge-EP, 15MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 130 W thermal design power (TDP),
FCLGA 2011-pin socket)1
2,
3
|
670537-001
|
|
Intel Xeon E5-2667 v2 Eight-Core 64-bit
processor - 3.00 GHz (Ivy Bridge-EP, 25MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 130 W thermal design power (TDP),
socket FCLGA 2011)1
|
730247-001
|
|
Intel Xeon E5-2670 Eight-Core 64-bit processor -
2.60 GHz (Sandy Bridge-EP, 20MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 115 W thermal design power (TDP),
FCLGA 2011-pin socket)1
2,
3
|
670523-001
|
|
Intel Xeon E5-2670 v2 Ten-Core 64-bit processor
- 2.50 GHz (Ivy Bridge-EP, 25MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 115 W thermal design power (TDP),
socket FCLGA 2011) 1
|
730236-001
|
|
Intel Xeon E5-2680 Eight-Core 64-bit processor -
2.70 GHz (Sandy Bridge-EP, 20MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 130 W thermal design power (TDP),
FCLGA 2011-pin socket) 1
2,
3
|
670522-001
|
|
Intel Xeon E5-2680 v2 Ten-Core 64-bit processor
- 2.80 GHz (Ivy Bridge-EP, 25MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 115 W thermal design power (TDP),
socket FCLGA 2011) 1
|
730235-001
|
|
Intel Xeon E5-2690 Eight-Core 64-bit processor -
2.90 GHz (Sandy Bridge-EP, 20MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 135 W thermal design power (TDP),
socket FCLGA 2011) 1
2,
3
|
670521-001
|
|
Intel Xeon E5-2690 v2 Ten-Core 64-bit processor
- 3.00 GHz (Ivy Bridge-EP, 25MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 130 W thermal design power (TDP),
FCLGA 2011 socket) 1
|
730234-001
|
|
14
|
Memory:
|
|
2GB, 1333 MHz, PC3L-10600E-9, DDR3, single-rank x8, 1.35 V, unbuffered with ECC dual in-line memory module (UDIMM)
|
664694-001
|
|
2GB, 1600 MHz, PC3L-12800E-11, DDR3, single-rank x8, 1.35 V, unbuffered with ECC dual in-line memory module (UDIMM) 1
|
715279-001
|
|
2GB, 1866 MHz, PC3-14900E-13, DDR3, Single-Rank x8, 1.50 V, Unbuffered with ECC Dual In-Line Memory Module (UDIMM) 1
|
715269-001
|
|
4GB, 1866 MHz, PC3-14900E-13, DDR3, Single-Rank x8, 1.50 V, Unbuffered with ECC Dual In-Line Memory Module (UDIMM) 1
|
715270-001
|
|
4GB, 1866 MHz, PC3-14900R-13, DDR3, dual-rank x4, 1.50 V, registered dual in-line memory module (RDIMM) 1
|
715272-001
|
|
4GB, 1600 MHz, PC3-12800R-11, DDR3, Single-Rank x4, 1.50 V, registered dual in-line memory module (DIMM) 1
|
664689-001
|
|
4GB, 1600 MHz, PC3L-12800R-11, DDR3, single-rank x4, 1.35 V, registered dual in-line memory module (RDIMM)
|
715282-001
|
|
4GB, 1600 MHz, PC3L-12800E-11, DDR3, single-rank x8, 1.35 V, unbuffered with ECC dual in-line memory module (UDIMM)
|
715280-001
|
|
4GB, 1333 MHz, PC3L-10600R-9, DDR3, single-rank x4, 1.35 V, registered dual in-line memory module (RDIMM)1
|
664688-001
|
|
4GB, 1333 MHz, PC3L-10600E-9, DDR3, dual-rank x8, 1.35 V, unbuffered with ECC dual in-line memory module (UDIMM)1
|
664695-001
|
|
8GB, 1866 MHz, PC3-14900E-13, DDR3, Dual-Rank x8, 1.50 V, Unbuffered with ECC Dual In-Line Memory Module (UDIMM)1
|
715271-001
|
|
8GB, 1600 MHz, PC3L-12800E-11, DDR3, Dual-Rank x8, 1.35 V, Unbuffered with ECC Dual In-Line Memory Module (UDIMM)1
|
715281-001
|
|
8GB, 1600 MHz, PC3L-12800R-11, DDR3, dual-rank x4, 1.35 V, registered dual in-line memory module (RDIMM)1
|
715283-001
|
|
8GB, 1866 MHz, PC3-14900R-13, DDR3, dual-rank x4, 1.50 V, registered dual in-line memory module (RDIMM)1
|
715273-001
|
|
8GB, 1866 MHz, PC3-14900R-13, DDR3, quad-rank x4, 1.50 V, registered dual in-line memory module (DIMM)1
|
735303-001
|
|
8GB, 1600 MHz, PC3L-12800R-11, DDR3, quad-rank x4, 1.35 V, registered dual in-line memory module (DIMM)1
|
735302-001
|
|
8GB, 1600 MHz, PC3-12800R-11, DDR3, single-rank x4, 1.50 V, registered dual in-line memory module (DIMM)1
|
664691-001
|
|
8GB, 1333 MHz, PC3L-10600R-9, DDR3, dual-rank x4, 1.35 V, registered dual in-line memory module (RDIMM)1
|
664690-001
|
|
8GB, 1333 MHz, PC3L-10600E-9, DDR3, dual-rank x8, 1.35 V, unbuffered with ECC dual in-line memory module (UDIMM)1
|
664696-001
|
|
8GB, 1600 MHz, PC3-12800R-11, DDR3, dual-rank x4, 1.50 V, registered dual in-line memory module (DIMM)1
|
698807-001
|
|
16GB, 1600 MHz, PC3-12800R-11, DDR3, dual-rank x4, 1.50 V, registered dual in-line memory module (DIMM)1
|
684031-001
|
|
16GB, 1600 MHz, PC3L-12800R-11, DDR3, quad-rank x4, 1.35 V, registered dual in-line memory module (RDIMM)1
|
715284-001
|
|
16GB, 1866 MHz, PC3-14900R-13, DDR3, quad-rank x4, 1.50 V, registered dual in-line memory module (RDIMM)1
|
715274-001
|
|
16GB, 1333 MHz, PC3L-10600R-9, DDR3, dual-rank x4, 1.35 V, registered dual in-line memory module (RDIMM)1
|
664692-001
|
|
16GB, 1333 MHz, PC3-10600H-9, DDR3, Dual-Rank x4, 1.50 V, HyperCloud Dual In-Line Memory Module (HDIMM)1
|
684032-001
|
|
32GB, 1333 MHz, PC3L-10600L-9, DDR3, Quad-Rank x4, 1.35 V, Load Reduced Dual In-Line Memory Module (LRDIMM)1
|
664693-001
|
|
32GB, 1866 MHz, PC3-14900L-13, DDR3, quad-rank x4, 1.50 V, load reduced dual in-line memory module (LRDIMM)1
|
715275-001
|
|
15
|
System board
|
|
System I/O board (motherboard) assembly - For
use with latch type (Caged) processor heatsinks - Includes subpan,
cables, left and right cable routing guides, thermal grease, alcohol
pad, and instruction card
|
718781-001
|
|
System I/O board (motherboard) assembly - For
use with screw-down type processor heatsinks - Includes subpan, cables,
left and right cable routing guides, thermal grease, alcohol pad, and
instruction card1
|
732150-001
|
|
16
|
Dual-rotor hot-pluggable fan module assembly - Includes the locking latch
|
822531-001
|
17
|
DVD-ROM drives:
|
|
SATA DVD-ROM optical drive (Jack Black color) - 8X DVD-ROM read, 24X CD-ROM read, 9.5 mm (0.374 inch) height
|
652296-001
|
|
SATA DVD-RW optical drive (Jack Black color) - 8X DVD-ROM read, 9.5 mm (0.374 inch) height1
|
652297-001
|
|
18
|
Hard drives:
|
|
72GB hot-plug dual-port SAS hard disk drive -
15,000 RPM, 6 Gb/s transfer rate, 2.5-inch small form factor (SFF),
Enterprise, SmartDrive Carrier (SC) - Not for use in MSA products
|
653949-001
|
|
100GB hot-plug Solid State Drive (SSD) - SATA
interface, 3 Gb/s transfer rate, 2.5-inch small form factor (SFF),
Multi-Level Cell (MLC), SmartDrive Carrier (SC)1
|
653965-001
|
|
100GB hot-plug Solid State Drive (SSD) - SATA
interface, 3 Gb/s transfer rate, 3.5-inch large form factor (LFF),
Multi-Level Cell (MLC), Enterprise Mainstream, SmartDrive Carrier (SC)1
|
653968-001
|
|
146GB hot-plug dual-port SAS hard disk drive -
15,000 RPM, 6 Gb/s transfer rate, 2.5-inch small form factor (SFF),
Enterprise, SmartDrive Carrier (SC) - Not for use in MSA products1
|
653950-001
|
|
200GB hot-plug Solid State Drive (SSD) - SATA
interface, 3 Gb/s transfer rate, 2.5-inch small form factor (SFF),
Multi-Level Cell (MLC), SmartDrive Carrier (SC)1
|
653966-001
|
|
200GB hot-plug Solid State Drive (SSD) - SATA
interface, 3 Gb/s transfer rate, 3.5-inch large form factor (LFF),
Multi-Level Cell (MLC), Enterprise Mainstream, SmartDrive Carrier (SC)1
|
653969-001
|
|
200GB hot-plug Solid State Drive (SSD) - SAS
interface, 6 Gb/s transfer rate, 2.5-inch small form factor (SFF),
Single-Level Cell (SLC), SmartDrive Carrier (SC)1
|
653961-001
|
|
300GB hot-plug dual-port SAS hard disk drive -
10,000 RPM, 6 Gb/s transfer rate, 2.5-inch small form factor (SFF),
Enterprise, SmartDrive Carrier (SC) - Not for use in MSA products1
|
653955-001
|
|
300GB hot-plug dual-port SAS hard disk drive -
15,000 RPM, 6 Gb/s transfer rate, 2.5-inch small form factor (SFF),
Enterprise, SmartDrive Carrier (SC) - Not for use in MSA products1
|
653960-001
|
|
400GB hot-plug Solid State Drive (SSD) - SATA
interface, 3 Gb/s transfer rate, 2.5-inch small form factor (SFF),
Multi-Level Cell (MLC), SmartDrive Carrier (SC)1
|
653967-001
|
|
400GB hot-plug Solid State Drive (SSD) - SATA
interface, 3 Gb/s transfer rate, 3.5-inch large form factor (LFF),
Multi-Level Cell (MLC), Enterprise Mainstream, SmartDrive Carrier (SC)1
|
653970-001
|
|
400GB hot-plug Solid State Drive (SSD) - SAS
interface, 6 Gb/s transfer rate, 2.5-inch small form factor (SFF),
Multi-Level Cell (MLC), SmartDrive Carrier (SC)1
|
653963-001
|
|
400GB hot-plug Solid State Drive (SSD) - SAS
interface, 6 Gb/s transfer rate, 2.5-inch small form factor (SFF),
Single-Level Cell (SLC), SmartDrive Carrier (SC)1
|
653962-001
|
|
450GB hot-plug dual-port SAS hard disk drive -
10,000 RPM, 6 Gb/sec transfer rate, 2.5-inch small form factor (SFF),
Enterprise, SmartDrive Carrier (SC) - Not for use in MSA products1
|
653956-001
|
|
450GB hot-plug dual-port SAS hard disk drive -
15,000 RPM, 6 Gb/s transfer rate, 3.5-inch large form factor (LFF),
Enterprise, SmartDrive Carrier (SC) - Not for use in MSA products1
|
653951-001
|
|
500GB hot-plug dual-port SAS hard disk drive -
7,200 RPM, 6 Gb/s transfer rate, 2.5-inch small form factor (SFF),
Midline, SmartDrive Carrier (SC) - Not for use in MSA products1
|
653953-001
|
|
500GB hot-plug SATA hard disk drive - 7,200
RPM, 6 Gb/s transfer rate, 2.5-inch small form factor (SFF), Midline,
SmartDrive Carrier (SC)1
|
656107-001
|
|
500GB hot-plug SATA hard disk drive - 7,200
RPM, 6 Gb/s transfer rate, 3.5-inch large form factor (LFF), midline,
SmartDrive Carrier (SC) - Not for use in MSA products1
|
658103-001
|
|
600GB hot-plug dual-port SAS hard disk drive -
10,000 RPM, 6 Gb/s transfer rate, 2.5-inch small form factor (SFF),
Enterprise, SmartDrive Carrier (SC) - Not for use in MSA products1
|
653957-001
|
|
600GB SAS hard disk drive - 15,000 RPM, 6 Gb/s
transfer rate, 3.5-inch large form factor (LFF), Enterprise, SmartDrive
carrier (SC), hot-plug, dual-port (DP)1
|
653952-001
|
|
800GB hot-plug Solid State Drive (SSD) - SAS
interface, 6 Gb/s transfer rate, 2.5-inch small form factor (SFF),
Multi-Level Cell (MLC), SmartDrive Carrier (SC)1
|
653964-001
|
|
900GB hot-plug dual-port SAS hard disk drive -
10,000 RPM, 6 Gb/s transfer rate, 2.5-inch small form factor (SFF),
Enterprise, SmartDrive Carrier (SC) - Not for use in MSA products1
|
653971-001
|
|
1TB hot-plug dual-port SAS hard disk drive -
7,200 RPM, 6 Gb/s transfer rate, 2.5-inch small form factor (SFF),
Midline, SmartDrive Carrier (SC) - Not for use in MSA products1
|
653954-001
|
|
1TB hot-plug dual-port SAS hard disk drive -
7,200 RPM, 6Gb/sec transfer rate, 3.5-inch large form factor (LFF),
Midline, SmartDrive Carrier (SC) - Not for use in MSA products1
|
653947-001
|
|
1TB hot-plug SATA hard disk drive - 7,200 RPM, 6
Gb/s transfer rate, 2.5-inch small form factor (SFF), Midline,
SmartDrive Carrier (SC) - Not for use in MSA products1
|
656108-001
|
|
1TB hot-plug SATA hard disk drive - 7,200 RPM, 6
Gb/s transfer rate, 3.5-inch large form factor (LFF), Midline,
SmartDrive Carrier (SC) - Not for use in MSA products1
|
657739-001
|
|
2TB hot-plug dual-port SAS hard disk drive -
7,200 RPM, 6 Gb/s transfer rate, 3.5-inch large form factor (LFF),
Midline, SmartDrive Carrier (SC) - Not for use in MSA products1
|
653948-001
|
|
2TB hot-plug SATA hard disk drive - 7,200 RPM,
6 Gb/s per second transfer rate, 3.5-inch large form factor (LFF),
midline, SmartDrive carrier (SC) - Not for use in MSA products1
|
658102-001
|
|
3TB hot-plug dual-port SAS hard disk drive -
7,200 RPM, 6 Gb/s transfer rate, 3.5-inch large form factor (LFF),
Midline, SmartDrive Carrier (SC) - Not for use in MSA products1
|
653959-001
|
|
3TB hot-plug SATA hard disk drive - 7,200 RPM, 6
Gb/s transfer rate, 3.5-inch large form factor (LFF), Midline,
SmartDrive Carrier (SC) - Not for use in MSA products1
|
628182-001
|
|
19
|
Cache module
1:
|
|
512MB flash backed write cache (FBWC) memory
module, 40-bit wide - Does not include the controller board or capacitor
module - For use with the P222 Smart Array controller
|
633540-001
|
|
1GB flash backed write cache (FBWC) memory
module, 72-bit wide - Does not include the controller board or capacitor
module - For use with the P420 and P421 Smart Array controllers
|
633542-001
|
|
2GB flash backed write cache (FBWC) memory
module, 72-bit wide - Does not include the controller board or capacitor
module - For use with the P420, P421, P430, P431, and 822 Smart Array
controllers
|
633543-001
|
|
20
|
Miscellaneous cable kit - Includes the front
video adapter cable, embedded SATA cable, Capacitor Pack with 36-inch
cable (Provides back up power to the FBWC memory module), and mini-SAS
cable with straight connector to left connector (33-inches long)
|
671353-0014
|
Capacitor pack with 914mm (36 inch) long cable -
For use with 2GB cache module - Provides back up power to the
flash-based write cache (FBWC) memory module for up to 80 seconds in the
event of a system power failure - For use with Smart Array controllers
|
660093-001
|
|
21
|
PCI riser board options:
|
|
PCIe riser board - x8 slot, low profile1
|
667866-001
|
|
PCIe riser board - x16 slot, full height, half length1
|
667867-001
|
|
PCIe riser board - x16 bus, low profile form factor
NOTE: For the DL360p SE Gen 8 ONLY
|
713080-001
|
|
Miscellaneous:
|
||
22
|
HP Trusted Platform Module (TPM)1
|
450168-001
|
23
|
Battery for real-time clock (RTC) - 3.0 V, 220 mAh, lithium coin cell, 20 mm diameter, 3.2 mm height (CR2032) 1
|
234556-001
|
24
|
AC power cord (Black) - 13AWG, 3.6m (12 ft)
long - Has straight C13 (F) plug for power output (For 120 V in USA,
Canada, and Mexico)1
|
187335-001
|
Cables:
|
||
25
|
Hard drive data cable or mini-SAS cable, 45 cm (18 in)1
|
667874-001
|
26
|
Hard drive data cable or mini-SAS cable, 64 cm (25 in)1
|
667875-001
|
27
|
Hard drive backplane power cable - Connects between the system I/O board and the hard drive backplane1
|
667873-001
|
28
|
Miscellaneous cable kit - Includes the front
video adapter cable, embedded SATA cable, Capacitor Pack with 36-inch
cable (Provides back up power to the FBWC memory module), and mini-SAS
cable with straight connector to left connector (33-inches long)1
|
671353-0014
|
29
|
SATA DVD drive cable - Connects between the
rear of the Slimline DVD drive and the system I/O board - For use with
8-bay SFF hard drive models and 4-bay LFF hard drive models1
|
667879-001
|
30
|
Chipset SATA cable1
|
671353-0014
|
31
|
Mini-SAS straight cable, 83.82 cm (33 in)
|
|
32
|
Optional system insight display (SID) /power
switch module assembly - Includes the SID assembly, power switch, UID
switch, status LEDs, and USB connector - For use with servers configured
with small form factor (SFF) drive bays
|
777288-001
|
NOTE: 1: Not shown in Figure 2.
2: All processors in this HP ProLiant server must have the same cache size, speed, number of cores, and rated maximum power consumption. 3: Be sure to use the correct spare part when replacing processors, heatsinks, or system boards. 4. Part number 671353-001 is a miscellaneous cable kit that includes the front video adapter cable, Chipset SATA cable, Mini-SAS straight cable and FBWC capacitor pack. |
اگر قبلا در بیان ثبت نام کرده اید لطفا ابتدا وارد شوید، در غیر این صورت می توانید ثبت نام کنید.