New model specific parts lists

IMPORTANT: To obtain current part number information for a specific product model, use the Standard Models page for this product family.

Click here to go to the Standard Models page for all model specific information and to access the product model parts lists .

  • The product Standard Models page now links the model SKU numbers to the spare parts list for each model found on the HPE PartSurfer web site. (To report missing or incorrect parts information in PartSurfer, please use the "Contact us" and "Missing or incorrect data" links within the PartSurfer web site utility.)

  • To look up RoHS-compliant information in PartSurfer, use the component's option part number or the sales order number for a system in which the component is used (Available in the QuickSpecs or Standard Models page).

top

Air baffle

Description
Spare Part Number
SPS - Baffle system
875054-001

top

Access panel

Description
Spare Part Number
SPS - Top cover Small Form Factor (SFF) W/label
875052-001
SPS - Top cover Large Form Factor (LFF) W/label
875053-001

top

FlexibleLOM adapter

Description
Spare Part Number
InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP (FlexibleLOM) adapter - ConnectX-3 pro architecture, InfiniBand bandwidth up to 56 Gb/s Fourteen Data Rate (FDR), Ethernet bandwidth up to 40 Gb/s, PCIe 3.0
764737-001
InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+ Quad Small Form-factor Pluggable (QSFP) adapter
764736-001

top

System board

Description
Spare Part Number
SPS - PCA system input-output W/SUBPAN 380 Gen10
875073-001
SPS - PCA system input-output W/SUBPAN 388 Gen10
875074-001

top

Backplane

Description
Spare Part Number
SPS - PCA 8-SFF SAS backplane 12 Gbs
878543-001
SPS - PCA 8-SFF premium HDD backplane
874933-001
SPS - PCA 2-SFF SAS rear backplane
875064-001
SAS/SATA backplane board - For the front 2-bay SFF hard drive cage - Up to 12 Gbs transfer speed - Optional board for configurations requiring more than eight hard drives and no optical drive - Mounts on the rear of the drive cage
775401-001
SPS - PCA 2SFF NVMe backplane
875080-001
SPS - PCA 3-LFF SAS rear backplane
875081-001
SPS - PCA 4-LFF SAS backplane
875082-001
SPS - PCA 8-SFF NVMe backplane
872971-001

top

PCI riser cage

Description
Spare Part Number
SPS - PCA 3S 2 x 8 x 16 PCI-E M.2 riser
877946-001
SPS - PCA 3S 2 x 8 x 16 PCI-E riser
875058-001
SPS - PCA 2-S x16 x16 PCI-E S1/2 riser
875059-001
SPS - PCA x 16 x 16 PCI-E S2/3 riser
875060-001
SPS - PCA 1-S x16 PCI-E tertiary riser
875061-001
SPS - PCA 2P slimline tertiary riser
875062-001
SPS - PCA 1-S x16 1U riser
875085-001
SPS - PCA 3 x8 / x1 slimline riser
875086-001
SPS - PCA 4-S x8 slimline riser
875087-001
Primary and secondary
SPS - Cage PCI riser
875056-001
Tertiary
SPS - Cage bfly riser DC/x16 2U
875057-001

top

Chassis

Description
Spare Part Number
SPS - Ear standard SFF left/right kit
875083-001
SPS - Ear power/UID LFF right+left kit
875084-001
SPS - Switch hood intrusion
878412-001

top

Fan

Description
Spare Part Number
SPS - Fan cage
875055-001
SPS - Fan module standard
875075-001
SPS - Fan module high performance
875076-001

top

Rail kit

Description
Spare Part Number
Easy install rack mount slide rail kit - For 2U high SFF model Servers
744114-001
Easy install rack mount slide rail kit - For 2U high LFF model Servers
744115-001
Cable management arm kit - Guides the power and interface cables to prevent binding when the server is slid in and out of the rack - Mounts to the rear of the rack
744116-001

top

Cable

Description
Spare Part Number
Mini-SAS cable kit - For the front or rear 2-bay SFF hard drive cage - Includes a mini-SAS to mini-SAS cable and a mini-SAS to SATA cable
784625-001
Mini-SAS cable assembly kit (Includes two mini-SAS cables) - For connecting the 8-bay SFF hard drive cage to the drive controller board
784621-001
SPS - Cable mini-SAS SFF kit
875089-001
SPS - Cable mini-SAS LFF kit
875090-001
SPS - Cable 4P slimline NVMe prim riser box 3
875091-001
SPS - Cable slimline NVMe direct attach kit
875092-001
SPS - Cable AROC to shiner 36p port1+2 kit
875093-001
Mini-SAS cable kit (Includes six cables) - For connecting between the 8-bay and 2-bay SFF hard drive cages and the H240 host bus adapter or the P440ar controller board
784629-001
SPS - Cable mini-SAS shiner kit
875094-001
SPS - Cable data cables kit
875095-001
SATA optical drive cable, 780 mm (30.7 in) long - Connects between the optical drive and the system input-output board
784623-001
SPS - Cable power cables kit
875096-001
SPS - Cable GPU cables kit
875097-001

top

Miscellaneous blanks

Description
Spare Part Number
SPS - Misc blanks kit front
875069-001
SPS - Misc blanks kit rear
875067-001
SPS - Misc blanks/bracket kit 2SFF rear
875068-001

top

Dual In-line Memory Module (DIMM)

Description
Spare Part Number
SPS - DIMM 8GB PC4-2666V-R 1Gx8
850879-001
16GB PC4-2666V-R, registered Synchronous Dynamic Random Access Memory (SDRAM), operated in a Dual Data Rate (DDR4) mode, packaged in a DIMM, organized as 2G x 72
850880-001
SPS - DIMM 16GB PC4-2666V-R 1G x 8
868846-001
32GB PC4-2666V-R, registered SDRAM, operated in a DDR4 mode, packaged in a DIMM, organized as 4G x 72
850881-001
64GB PC4-2666V-R, registered SDRAM, operated in a DDR4 mode, packaged in a DIMM, organized as 8G x 72
850882-001

top

Processor

Description
Spare Part Number
SPS - CPU SKL Xeon-B 31xx 6c 85 W
875709-001
SPS - CPU SKL Xeon-B 31xx 8c 85 W
875710-001
SPS - CPU SKL Xeon-S 41xx 8c 85 W
875712-001
SPS - CPU SKL Xeon-S 41xx 8c 85 W
875711-001
SPS - CPU SKL Xeon-S 41xx 4c 85 W
875714-001
SPS - CPU SKL Xeon-S 41xx 10c 85 W
875713-001
SPS - CPU SKL Xeon-S 41xx 12c 85 W
875716-001
2.4 GHz Intel Xeon-G 5115 processor
878082-001
SPS - CPU SKL Xeon-G 51xx 12c 105 W
875717-001
SPS - CPU SKL Xeon-G 51xx 14c 105 W
875718-001
SPS - CPU SKL Xeon-G 5122 4c 105 W
875719-001
Intel Xeon-Gold 6126 twelve cores, processor - 2.60 GHz, 125 W Thermal Design Power (TDP), skylake-SP, socket FCLGA 3647
875720-001
SPS - CPU SKL Xeon-G 6128 6c 115 W
875721-001
Intel Xeon - Gold 6130 sixteen cores, processor - 2.10 GHz, 125 W TDP, skylake-SP, socket FCLGA 3647
874736-001
SPS - CPU SKL Xeon-G 6132 14c 133 W
875722-001
SPS - CPU SKL Xeon-G 6134 8c 130 W
875723-001
SPS - CPU 6134M SKL Xeon-G 8c 1
878083-001
SPS - CPU SKL Xeon-G 6136 12c
875724-001
SPS - CPU SKL Xeon-G 6138 20c 2.0G 125 W
874735-001
Intel Xeon-G 6140 eighteen-core 64-bit processor - 2.30 GHz (Skylake-SP, 140 W TDP)
874734-001
SPS - CPU 6140M SKL Xeon-G 18c
878084-001
Intel Xeon-Gold 6142 sixteen-cores, processor - 2.60 GHz, 150 W TDP, skylake-SP, socket FCLGA 3647
874733-001
SPS - CPU 6142M SKL Xeon-G 16c
878085-001
Intel Xeon-Gold 6148 twenty-cores, processor - 2.40 GHz, 150 W TDP, skylake-SP, socket FCLGA 3647
874732-001
SPS - CPU SKL Xeon-G 6150 18c 2.7G 165 W
874731-001
SPS - CPU SKL Xeon-G 6152 22c 2.1G 140 W
874730-001
SPS - CPU SKL Xeon-G 6154 18c 200 W
875727-001
SPS - CPU SKL Xeon-P 8153 16c 120 W
875728-001
SPS - CPU SKL Xeon-P 8156 4c 105 W
875732-001
SPS-CPU SKL Xeon-P 8158 12c 150 W
875733-001
Intel Xeon platinum 8160 twenty-four-core 64-bit processor - 2.10 GHz (Skylake-SP, 33MB level-3 cache, 150 W TDP, socket LGA 3647)
874729-001
SPS - CPU 8160M SKL Xeon-P 24c
878086-001
SPS - CPU SKL Xeon-P 8164 26c 150 W
875729-001
SPS - CPU SKL Xeon-P 8168 24c 205 W
875730-001
SPS- CPU SKL Xeon-P 8170 26c 2.1G 165 W
874728-001
SPS - CPU 8170M SKL Xeon-P 26c
878087-001
SPS - CPU SKL Xeon-P 8176 28c 2.1G 165 W
874727-001
SPS - CPU SKL Xeon-P 8176 28c 2.1G 165 W
874727-001
SPS - CPU 8176M SKL Xeon-P 28c
878088-001
SPS - CPU SKL Xeon-P 8180 28c 205 W
875731-001

top

Graphics Processing Unit (GPU)

Description
Spare Part Number
SPS - PCA, NVIDIA Tesla P4 8GB module
872321-001
SPS - PCA NVIDIA Quadro P4000
871970-001
SPS - PCA NVIDIA Quadro P2000
871969-001
Quadro P6000 3840 NVIDIA CUDA parallel processing cores, 24GB GDDR5X memory, 432 GB/s, ECC memory, DP (x4) with HDR support, DL-DVI(I),3-pin mini-DIN connector, SLI connector, one 8-pin auxiliary power connector
871968-001
PCA NVIDIA Tesla M10 quad GPU
870046-001
SPS - PCA, NVIDIA Tesla P40 24GB module
872323-001
SPS - PCA, NVIDIA Tesla P100 12GB module
877646-001
NVIDIA Tesla P100 PCIe 16GB computational accelerator
868585-001

top

Heatsink

Description
Spare Part Number
SPS - Heatsink STD
875070-001
SPS - Heatsink H/P
875071-001
SPS - Heatsink 1U standard
872452-001

top

Power supply

Description
Spare Part Number
SPS - PS, 1U 12 V 800 W HTPLG HVDC 277 V
866727-001
SPS - PS, 1U 12 V 800 W HTPLG 48 V dc G10
866728-001
SPS - PS, 1U 12 V 500 W HTPLG HE-P G10
866729-001
SPS - PS, 1U 12 V 800 W HTPLG HE-P G10
866730-001
SPS - PS, 1U 12 V 800 W HTPLG HE-T PLC
866793-001
SPS - PS, 1U 1600 W 12 V HTPLG red PL
863373-001

top

Controller

Description
Spare Part Number
SPS - PCA, AROC E208i-a SR Gen10 controller
836259-001
SPS - PCA, AROC P408i-a SR Gen10 controller
836260-001
SPS - PCA, AROC P816i-a SR Gen10 controller
836261-001
SPS - PCA H250 HBA 8i PCIe
836266-001
SPS - PCA H251 HBA 8e PCIe
836267-001
SPS - PCA, P408i-p SR Gen10 controller
836269-001
SPS - PCA SA P451/4GB controller 2ex4 HD SAS
836270-001
StoreFabric SN1600Q 32Gb - Single port Fibre Channel (FC) adapter
868140-001
StoreFabric SN1600Q 32Gb - Dual port FC adapter
868141-001
StoreFabric SN1600E 32Gb - Single port FC host adapter
869999-001
PCIe 1-port, 8GB, FC 81Q (QLogic) Host Bus Adapter (HBA) board - Has one fully independent 2/4/8Gb auto-negotiation short wave laser LC port - Requires one Low Profile (LP) (Or full height) x8 PCIe slot
489190-001
SN1200E 16Gb single port FC HBA
870001-001
SN1200E 16Gb dual port FC HBA
870002-001
PCIe 2-port, 8GB, FC 82Q (QLogic) HBA board - Has two fully independent 2/4/8Gb auto-negotiation short wave laser LC ports - Requires one LP (Or full height) x8 PCIe slot
489191-001
StoreFabric SN1100E 4-Port 16Gb FC HBA
853008-001
HPE StoreFabric 84E 4-Port 8Gb FC HBA
780686-001
HP 81E 8Gb 1-Port PCIe FC HBA
697889-001
HP 82E PCIe 2-Port 8Gb FC HBA module (Emulex)
697890-001
PCIe 4-port, 8GB, FC 84Q (QLogic) HBA board - Has four fully independent 2/4/8Gb auto-negotiation short wave laser LC ports - Requires one LP (Or full height) x8 PCIe slot
853009-001
HPE SN1100Q 16Gb 1p FC HBA
863010-001
StoreFabric SN1100Q 16Gb two port FC HBA
853011-001
HPE StoreFabric CN1100R - Dual port Converged Network Adapter (CNA)
706801-001
HPE StoreFabric CN1100R-T 10Gb CNA
872605-001
CN1200E 10Gb CNA
767078-001
StoreFabric CN1200E-T 10Gb CNA
827607-001

top

Drive

Description
Spare Part Number
1TB SAS drive - 12 Gb/s transfer rate, 7,500 rpm, 2.5-inch SFF, Midline (MDL), Smart Carrier (SC) - For use with Gen8/Gen9 or newer
832984-001
1TB hot-plug SAS HDD - 7,200 rpm, 12 Gb/s transfer rate, 2.5-inch SFF, MDL, 512e sector format, SC
765872-001
1TB SATA HDD - 7,200 rpm, 6 Gb/s transfer rate, 3.5-inch LFF, MDL, SC
862128-001
1TB SAS hard drive - 12 Gb/s interface, 7,200 rpm, 3.5-inch LFF, SC
846612-001
1TB hot-plug SATA HDD - 7,200 rpm, 6 Gb/s transfer rate, 2.5-inch SFF, MDL, 512e sector format, SC
765868-001
1TB hot-plug SATA HDD - 7,200 rpm, 6 Gb/s transfer rate, 2.5-inch SFF, MDL, SC - Not for use in MSA products
656108-001
2TB hot-plug SAS HDD - 12 Gb/s transfer rate, 7,200 rpm, 2.5-inch SFF, MDL, 512e format, SC - For use with Gen8/Gen9 or newer
765873-001
2TB HDD - SAS interface, 12 Gb/s interface, 3.5-inch LFF, 7,200 rpm, SC, dual port, digitally signed firmware
872744-001
2TB SAS hard drive - 7,200 rpm, 3.5-inch LFF, 12 Gb/s interface, SC, MDL SAS - For use with Gen8/Gen9 or newer
819078-001
2TB HDD - SATA interface, 6 Gb/s interface, 3.5-inch LFF, 7,200 rpm, SC, digitally signed firmware
872771-001
2TB SATA hard drive - 6 Gb/s interface, 7,200 rpm, 3.5-inch LFF, SC, MDL
862126-001
2TB hot-plug SATA HDD - 6 Gb/s transfer rate, 7,200 rpm, 2.5-inch SFF, MDL, 512e sector format, SC
765869-001
3TB SAS hard drive - 6 Gb/s interface, 7,200 rpm, 3.5-inch LFF, SC
862129-001
3TB SAS hard drive - 12 Gb/s interface, 7,200 rpm, 3.5-inch LFF, SC - For use with Gen8/Gen9 or newer
846614-001
4TB SAS hard drive - 12 Gb/s transfer rate interface, 7,200 rpm, 3.5-inch LFF, MDL, 512e format, digitally signed firmware, SC
862141-001
4TB HDD - SAS interface, 12 Gb/s interface, 3.5-inch LFF, 7,200 rpm, SC, dual port, digitally signed firmware
872745-001
4TB SAS hard drive - 7,200 rpm, 3.5-inch LFF, 6 Gb/s interface, SC, MDL SAS - For use with Gen8/Gen9 or newer
819079-001
4TB HDD - SATA interface, 6 Gb/s interface, 3.5-inch LFF, 7,200 rpm, SC, digitally signed firmware
872772-001
4TB SATA hard drive - 6 Gb/s interface, 7,200 rpm, 3.5-inch LFF, SC, MDL
862127-001
4TB SATA hard drive - 6 Gb/s transfer rate interface, 7,200 rpm, 3.5-inch LFF, MDL, 512e format, digitally signed firmware, SC
862139-001
6GB SATA MDL hard drive - 6 Gb/s SATA interface, 7,200 rpm, 3.5-inch LFF, SC
846608-001
6TB SATA hard drive - 6 Gb/s transfer rate interface, 7,200 rpm, 3.5-inch LFF, MDL, 512e format, digitally signed firmware, SC
862138-001
6TB SAS hard drive - 12 Gb/s transfer rate interface, 7,200 rpm, 3.5-inch LFF, MDL, 512e format, digitally signed firmware, SC
862140-001
8TB SATA hard drive - 6 Gb/s interface, 7,200 rpm, 3.5-inch LFF, LP, SC, 512e format, digitally signed firmware
861609-001
8TB SATA hard drive - 6 Gb/s interface, 7,200 rpm, 3.5-inch LFF, SC, MDL, 512e format
820033-001
10TB SATA hard drive - 6 Gb/s interface, 7,200 rpm, 3.5-inch LFF, 512e format
857967-001
6TB SAS MDL hard drive - 12 Gb/s SAS interface, 7,200 rpm, 3.5-inch LFF, SC - For use with Gen8/Gen9 or newer
846610-001
8TB SAS hard drive - 12 Gb/s interface, 7,200 rpm, 3.5-inch LFF, SC - For use with Gen8/Gen9 or newer
861607-001
8TB SAS HDD - 12 Gb/s transfer rate, 7,200 rpm, 3.5-inch LFF, SC, 512e format, MDL - For use with Gen8/Gen9 or newer
820032-001
10TB SATA hard drive - 12 Gb/s interface, 7,200 rpm, 3.5-inch LFF, SC - For use with Gen8/Gen9 or newer
857965-001
300GB hot-plug SAS HDD - 10,000 rpm, 12 Gb/s transfer rate, 2.5-inch SFF, SC - For use with Gen8/Gen9 or newer
785410-001
300GB SAS hard drive - 12 Gb/s interface, 10,000 rpm, 2.5-inch SFF, SC, digitally signed firmware
872735-001
600GB SAS hard drive - 12 Gb/s interface, 10,000 rpm, 2.5-inch SFF, SC, digitally signed firmware
872736-001
600GB hot-plug SAS HDD - 12 Gb/s transfer rate, 10,000 rpm, 2.5-inch SFF, SC - For use with Gen8/Gen9 or newer
781577-001
900GB hot-plug SAS HDD - 12 Gb/s transfer rate, 10,000 rpm, 2.5-inch SFF, Enterprise, SC
785411-001
1.2TB hot-plug SAS HDD - 12 Gb/s transfer rate, 10,000 rpm, 2.5-inch SFF, SC - For use with Gen8/Gen9 or newer
781578-001
1.2TB SAS hard drive - 12 Gb/s interface, 10,000 rpm, 2.5-inch SFF, SC, digitally signed firmware
872737-001
1.8TB SAS hard drive - 12 Gb/s interface, 10,000 rpm, 2.5-inch SFF, Enterprise drive, 512e format, digitally signed firmware
872738-001
1.8TB hot-plug SAS HDD - 12 Gb/s transfer rate, 10,000 rpm, 2.5-inch SFF, Enterprise, 512e format, SC - For use with Gen8/Gen9 or newer
791055-001
300GB hot-plug SAS HDD - 12 Gb/s transfer rate, 15,000 rpm, 2.5-inch SFF, SC - For use with Gen8/Gen9 or newer
759546-001
300GB SAS hard drive - 12 Gb/s interface, 15,000 rpm, 2.5-inch SFF, Enterprise drive, SC, digitally signed firmware
870792-001
450GB hot-plug dual-port SAS HDD - 15,000 rpm, 12 Gb/s transfer rate, 2.5-inch SFF, SC - For use with Gen8/Gen9 or newer
759547-001
600GB SAS hard drive - 12 Gb/s interface, 15,000 rpm, 2.5-inch SFF, Enterprise drive, SC, digitally signed firmware
870794-001
600GB SAS hard drive - 12 Gb/s interface, 15,000 rpm, 2.5-inch SFF, Enterprise drive, 512e format, digitally signed firmware
870797-001
600GB hot-plug SAS HDD - 12 Gb/s transfer rate, 15,000 rpm, 2.5-inch SFF, SC - For use with Gen8/Gen9 or newer
759548-001
600GB hot-plug SAS HDD - 15,000 rpm, 12 Gb/s transfer rate, 2.5-inch SFF, Enterprise, 512e format, SC - For use with Gen8/Gen9 or newer
748435-001
900GB SAS hard drive - 12 Gb/s interface, 15,000 rpm, 2.5-inch SFF, Enterprise drive, SC, digitally signed firmware
870795-001
900GB SAS hard drive - 12 Gb/s interface, 15,000 rpm, 2.5-inch SFF, dual port, SC, digitally signed firmware, 512e format
870798-001
400GB Non-Volatile Memory express (NVMe) Solid State Drive (SSD) - NVMe interface, Write Intensive (WI), 2.5-inch SFF, Mainstream Endurance (ME), Smart Carrier 2 (SC2), Power Loss Protection (PLP) - Supports select Gen9 servers
765059-001
400GB NVMe SSD - NVMe interface, Read Intensive (RI), 2.5-inch SFF, Value Endurance (VE), SC2, PLP - Supports select Gen9 servers
765067-001
400GB NVMe SSD - NVMe interface, MU, 2.5-inch SFF, Light Endurance (LE), SC2, PLP - Supports select Gen9 servers
765063-001
800GB NVMe SSD - NVMe interface, WI, 2.5-inch SFF, ME, SC2, PLP - Supports select Gen9 servers
765060-001
800GB NVMe SSD - NVMe interface, MU, 2.5-inch SFF, LE, SC2, supports PLP - Supports select Gen9 servers
765064-001
1.2TB NVMe SSD - NVMe interface, RI, 2.5-inch SFF, VE, SC2, PLP - Supports select Gen9 servers
765068-001
1.6TB NVMe SSD - NVMe interface, WI, 2.5-inch SFF, ME, SC2, PLP - Supports select Gen9 servers only
765061-001
1.6TB NVMe SSD - NVMe interface, MU, 2.5-inch SFF, LE, SC2, supports PLP - Supports select Gen9 servers
765065-001
2.0TB NVMe SSD - PCIe NVMe interface, MU, 2.5-inch SFF, LE, SC2, supports PLP - Supports select Gen9 servers
765066-001
2.0TB NVMe SSD - PCIe NVMe interface, RI, 2.5-inch SFF, ME, SC2, PLP - Supports select Gen9 server
765069-001
2.0TB NVMe SSD - NVMe interface, WI, 2.5-inch SFF, ME, SC2, PLP - Supports select Gen9 servers
765062-001
120GB SATA SSD - 6 Gb/s interface, RI, M.2 form factor (2280), VE, supports power loss prevention
831995-001
120GB SATA SSD - 6 Gb/s interface, RI, M.2 form factor (2280), VE, supports power loss prevention - Supports DL/ML Gen9
781565-001
340GB SATA SSD - RI-2, M.2 type 2280 (80.0 × 22.0 x 3.5 mm) form factor, 6 Gb/s transfer rate, VE, supports PLP - Support DL/ML Gen9
781566-001
400GB hot-plug SSD - SAS interface, MU-3, 12 Gb/s transfer rate, 2.5-inch SFF, SC, supports PLP - For use with Gen8 servers and beyond
822784-001
480GB hot-plug SSD - SAS interface, RI-3, 12 Gb/s transfer rate, 2.5-inch SFF, SC, supports PLP - For use with Gen8 servers and beyond
817047-001
800GB hot-plug SSD - SAS interface, MU-3, 12 Gb/s transfer rate, 2.5-inch SFF, SC, supports PLP - For use with Gen8 servers and beyond
822786-001
960GB hot-plug SSD - SAS interface, RI-3, 12 Gb/s transfer rate, 2.5-inch SFF, SC, supports PLP - Gen8 servers and beyond only
817049-001
1.6TB hot-plug SSD - SAS interface, MU-3, 12 Gb/s transfer rate, 2.5-inch SFF, SC, supports PLP - Gen8 servers and beyond only
822788-001
1.92TB hot-plug SSD - SAS interface, RI-3, 12 Gb/s transfer rate, 2.5-inch SFF, SC, supports PLP - Gen8 and beyond only
817051-001
3.2TB hot-plug SSD - SAS interface, MU-3, 12 Gb/s transfer rate, 2.5-inch SFF, SC, supports PLP - For use with Gen8 servers and beyond
822790-001
3.84TB hot-plug SSD - SAS interface, RI-3, 12 Gb/s transfer rate, 2.5-inch SFF, SC, supports PLP - Gen8 and beyond only
817053-001
150GB hot-plug SSD - SATA interface, RI, 6 Gb/s transfer rate, 2.5-inch SFF, SC,digitally signed firmware
869575-001
200GB hot-plug SSD - SATA interface, WI-2, 6 Gb/s transfer rate, 2.5-inch SFF, SC, PLP - For use with Gen8 servers and beyond
805385-001
200GB hot-plug SSD - SATA interface, WI-2, 6 Gb/s transfer rate, 3.5-inch LFF, Smart Carrier Converter (SCC), PLP - For use with Gen8 servers and beyond
805386-001
240GB SATA SSD - 6 Gb/s transfer rate, RI, 2.5-inch SFF, SC, digitally signed firmware
868924-001
240GB SSD - SATA interface, 6 Gb/s transfer rate, 2.5-inch SFF, RI, SC, digitally signed firmware
869576-001
400GB SSD - SATA interface, 6 Gb/s interface, 2.5-inch SFF, WI-3, SC, digitally signed firmware
872512-001
400GB SSD - SATA interface, 6 Gb/s interface, 2.5-inch SFF, WI-3, SCC SFF to LFF tray digitally signed firmware
872513-001
400GB hot-plug SSD - SATA interface, WI-2, 6 Gb/s transfer rate, 2.5-inch SFF, SC, PLP - For use with Gen8 servers and beyond
805387-001
400GB hot-plug SSD - SATA interface, WI-2, 6 Gb/s transfer rate, 3.5-inch LFF, SCC, PLP - For use with Gen8 servers and beyond
805388-001
480GB SATA SSD - 6 Gb/s transfer rate, RI, 2.5-inch SFF, SC, digitally signed firmware
868926-001
480GB hot-plug SSD - SATA interface, MU-3, 6 Gb/s transfer rate, 2.5-inch SFF, PLP, SC, digitally signed firmware
872518-001
480GB hot-plug SSD - SATA interface, MU, 6 Gb/s transfer rate, 3.5-inch LFF, PLP, SCC, digitally signed firmware
872519-001
480GB SSD - SATA interface, 6 Gb/s transfer rate, 2.5-inch SFF, RI, SC, digitally signed firmware
869577-001
480GB SSD - SATA interface, 6 Gb/s data rate, 2.5-inch SFF, RI, SCC SFF to LFF, digitally signed firmware
869578-001
800GB SSD - SATA interface, 6 Gb/s interface, 2.5-inch SFF, WI-3, SC, digitally signed firmware
872514-001
800GB SSD - SATA interface, 6 Gb/s interface, 2.5-inch SFF, WI-3, SCC SFF to LFF, digitally signed firmware
872515-001
800GB hot-plug SSD - SATA interface, WI-2, 6 Gb/s transfer rate, 2.5-inch SFF, SC, PLP - For use with Gen8 servers and beyond
805389-001
800GB hot-plug SSD - SATA interface, WI-2, 6 Gb/s transfer rate, 3.5-inch LFF, SCC, PLP - For use with Gen8 servers and beyond
805390-001
960GB SATA SSD - SATA interface, RI, 2.5-inch SFF, SC, digitally signed firmware
868928-001
960GB SSD - SATA interface, 6 Gb/s transfer rate, 2.5-inch SFF, RI digitally signed firmware, SC
869580-001
960GB hot-plug SSD - SATA interface, MU-3, 6 Gb/s transfer rate, 2.5-inch SFF, SC, digitally signed firmware
872520-001
960GB hot-plug SSD - SATA interface, MU-3, 6 Gb/s transfer rate, 3.5-inch LFF, SCC, digitally signed firmware
872521-001
1.2TB hot-plug SSD - SATA interface, WI-2, 6 Gb/s transfer rate, 2.5-inch SFF, SC, PLP - For use with Gen8 servers and beyond
805391-001
1.2TB hot-plug SSD - SATA interface, WI-2, 6 Gb/s transfer rate, 3.5-inch LFF, SCC, PLP - For use with Gen8 servers and beyond
805392-001
1.6TB SSD - SATA interface, 6 Gb/s interface, 2.5-inch SFF, WI-3, SC, digitally signed firmware
872516-001
1.6TB SSD - SATA interface, 6 Gb/s interface, 2.5-inch SFF, WI-3, SCC SFF to LFF, digitally signed firmware
872517-001
1.6TB SSD - SATA interface, 6 Gb/s transfer rate, 2.5-inch SFF, RI digitally signed firmware, SC
869581-001
1.6TB SSD - SATA interface, 6 Gb/s transfer rate, 2.5-inch SFF, RI digitally signed firmware, SCC SFF to LFF tray
869582-001
1.9TB SATA SSD - SATA interface, RI, 2.5-inch SFF, SC, digitally signed firmware
868930-001
1.92TB SSD - SATA interface, 6 Gb/s transfer rate, 2.5-inch SFF, MU-3, SC, digitally signed firmware
872522-001
3.84TB SATA SSD - SATA interface, RI, 2.5-inch SFF, SC, digitally signed firmware
868932-001

top

Other parts

Description
Spare Part Number
Battery for Real-Time Clock (RTC) - 3.0 V, 220 mAh, lithium coin cell, 20 mm diameter, 3.2 mm height (CR2032)
319603-001
SPS - Bezel 2U
875065-001
SPS - Blank fan+latch M.cell+PCIe/T. RTNRs
875066-001
Rear serial port interface
875571-001
Optical drive blank (Cover) - To fill an empty optical drive bay
707300-001
SPS - PCA, SA PCIe SAS expander Gen10
876907-001
96 W smart Storage battery - One battery pack provides Flash Back Write Cache (FBWC) for all the drive controllers in the server - Connects to the system input-output board, 145 mm (5.7 in) long cable - Version 3
871264-001
SPS - Power module without SID
875077-001
SPS - Power/SID module w/label
875063-001
SPS - Power/ODD module LFF
875079-001
SPS - PCA LFF input-output UID
875088-001
SPS - PCA Trusted Platform Module (TPM) Gen10 TAA
872159-001
SPS - Thermal grease kit
777298-001