Item
|
Part Description
|
Spare Part Number
|
---|---|---|
1
|
Access panel
|
|
Access panel - Top cover for the 8-bay small form factor (SFF), and 8-bay large form factor (LFF) model servers
|
662534-001
|
|
Access panel - Top cover for the 25-bay small form factor (SFF), and 12-bay large form factor (LFF) model servers 1
|
696959-001
|
|
2
|
Fan cage assembly (includes the fan backplane
board) - Holds six fan modules - Mounts in the bottom of the chassis
between the hard drives and the system I/O board
|
662518-001
|
3
|
Hard drive cage, 8-bay Small Form Factor (SFF) -
Includes hard drive connector backplane board - Mounts in the 8-bay SFF
front panel cage (two can be used if no optical drive is needed)
|
670943-001
|
4
|
SFF front panel assembly (Front panel assembly contains power button assembly)
|
|
Front panel cage assembly, 8-bay Small Form
Factor (SFF) - Has openings for the 8-bay SFF hard drive cage and the
optical drive cage (or two SFF hard drive cages) - Includes cables and
left and right ears (no backplane board)
|
675602-001
|
|
Front panel cage assembly, 25-bay Small Form
Factor (SFF) hard drive - Includes the drive connector backplane board,
cables, and left and right ears 1
|
696958-001
|
|
5
|
LFF front panel assembly (Front panel assembly contains power button assembly)
|
|
Front panel cage assembly, 8-bay Large Form
Factor (LFF) hard drive and optical drive bay - Includes the drive
connector backplane board, cables, and left and right ears
|
675603-001
|
|
Front panel cage assembly, 12-bay Large Form
Factor (LFF) hard drive - Includes the drive connector backplane board,
cables, and left and right ears 1
|
670944-001
|
|
6
|
PCI riser cage
|
|
PCI riser cage - L-shaped metal structure that
mounts towards the rear of the server - Capable of mounting two or three
PCIe cards depending on which riser board is used (Does not include the
riser board)
|
662526-001
|
|
PCI riser cage, double-wide
|
709860-001
|
|
PCI riser cage, NEBS
|
709859-001
|
|
7
|
Airflow baffle
|
662527-001
|
8
|
Hard drive blank
1
|
|
Hard drive blank, SFF
|
667276-001
|
|
Hard drive blank, LFF
|
667279-001
|
|
9
|
Heatsink blank1
|
662522-001
|
10
|
DIMM blank
|
716110-001
|
11
|
Processor cage1
|
662537-001
|
12
|
Hardware blank kit contains: Optical device blank, fan blank, FlexibleLOM blank, PCI riser cage blank and expansion slot blank1
|
662519-001
|
13
|
Power supply blank cover
|
699833-001
|
14
|
2U security bezel assembly 1
|
662529-001
|
15
|
Plastic battery holder (12 LFF/25 SFF)1
|
687957-001
|
16
|
Miscellaneous hardware kit contains: Fan
bracket, left; fan bracket, right; DVD cable routing guide; DIMM guard;
Basepan cable retention clip1
|
662523-001
|
17
|
Miscellaneous hardware kit 2 contains:
Processor blank air deflector assembly, Fan bracket, left (12 LFF/25
SFF), Plastic battery holder (12 LFF/25 SFF), PCIe riser cage divider,
and Plastic battery holder, Velcro (12 LFF/25SFF)1
|
700383-001
|
18
|
Ball bearing rail kit, SFF
|
662535-001
|
19
|
Ball bearing rail kit, LFF
|
692480-001
|
20
|
Friction rail kit1
|
662536-001
|
21
|
Cable management arm (not supported withthe friction rail kit)1
|
675606-001
|
NOTE: 1: Not shown in the above figure.
|
System components
Item
|
Description
|
Spare Part Number
|
---|---|---|
22
|
Hot-pluggable fan module assembly - Includes the locking latch
|
662520-001
|
23
|
Power supplies, hot-plug:
|
|
a) 460 W AC Common Slot (CS) 'Gold' hot-plug
power supply - Installs in the computer chassis as primary or redundant
supply (92% efficiency) - Requires 100-240 V AC at 50/60 Hz
|
511777-001
|
|
b) 460 W AC Common Slot (CS) 'Platinum Plus'
hot-plug power supply - Installs in computer chassis as primary or
redundant supply (94% efficiency) - Requires 100-240 V AC at 50/60 Hz
|
660184-001
|
|
c) 500 W AC Common Slot (CS) '277 VAC' hot-plug
power supply - Installs in the computer chassis as primary or redundant
supply (94% efficiency) - Requires 200-277 V AC at 50/60 Hz
|
638549-001
|
|
d) 750 W AC Common Slot (CS) '277 VAC' hot-plug
power supply - Installs in the computer chassis as primary or redundant
supply (94% efficiency) - Requires 200-277 V AC at 50/60 Hz
|
674890-001
|
|
e) 750 W AC Common Slot (CS) 'Titanium'
hot-plug power supply - Installs in the computer chassis as primary or
redundant supply (96% efficiency) - Requires 200-240 V AC at 50/60 Hz
|
700287-001
|
|
f) 750 W AC Common Slot (CS) 'Gold' hot-plug
power supply - Installs in the computer chassis as primary or redundant
supply (92% efficiency) - Requires 100-240 V AC at 50/60 Hz
|
511778-001
|
|
g) 750 W AC Common Slot (CS) 'Platinum Plus'
hot-plug power supply - Installs in computer chassis as primary or
redundant supply (94% efficiency) - Requires 100-240 V AC at 50/60 Hz
|
660183-001
|
|
h) 750 W DC Common Slot (CS) 'Gold' hot-plug
power supply - Installs in the computer chassis as primary or redundant
supply (92% efficiency),
|
639173-001
|
|
i) 1200 W AC Common Slot (CS) '277 V AC'
hot-plug power supply - Installs in the computer chassis as primary or
redundant supply (91% efficiency) - Requires 200-277 V AC at 50/60 Hz
|
714349-001
|
|
j) 1200 W DC Common Slot (CS) '380 V DC'
hot-plug HVDC power supply - Installs in the computer chassis as primary
or redundant supply (92% efficiency) - Requires 240-380 V DC
|
704603-001
|
|
k) 1200 W AC Common Slot (CS) 'Platinum Plus'
hot-plug power supply - Installs in computer chassis as primary or
redundant supply (94% efficiency) - Requires 100-240 V AC at 50/60 Hz
|
660185-001
|
|
24
|
System board assembly
|
801939-001
|
25
|
Riser boards:
|
|
3-slot PCIe riser board (standard) - Includes one x16 slot, and two x8 slots
|
662524-001
|
|
2-slot PCIe riser board (optional) - Has two x16 slots - Mounts to the PCI riser cage 1
|
662525-001
|
|
26
|
Power supply backplane board assembly
|
662528-001
|
27
|
Systems Insight Display (SID) assembly - For
8-bay Large Form Factor (LFF) server models (12-bay models have no SID) -
Includes cables
|
662515-001
|
28
|
Systems insight display (SID) assembly - For 8-bay or 16-bay small form factor (SFF) servers - Includes cables 1
|
662516-001
|
29
|
HPE Trusted Platform Module1
|
505836-001
|
30
|
FlexibleLOM:
|
|
FlexibleLOM Ethernet 1Gb 4-port 331FLR adapter -
Has four 10/100/1000BASE-T RJ45 ports - Requires one x4 (Gen 2) PCI
Express slot (mechanically compatible with x8 and x16 PCI Express slots)
|
789897-001
|
|
HP 10GbE 2-port, 530FLR Adapter FIO Kit
|
649869-001
|
|
HP Ff 10Gb 2-port, 554FLR-SFP+ Adapter FIOKit
|
634026-001
|
|
HP InfiniBand FDR/EN 10/40Gb 2-port,544FLR-QSFP Adapter
|
656090-001
|
|
HP InfiniBand QDR/EN 10Gb 2-port,544FLR-QSFP Adapter
|
656091-001
|
|
31
|
Memory:
|
|
a) 2GB, 1333 MHz, PC3L-10600E-9, DDR3, single-rank x8, 1.35 V, unbuffered with ECC dual in-line memory module (UDIMM)
|
664694-001
|
|
b) 2GB, 1866 MHz, PC3-14900E-13, DDR3, Single-Rank x8, 1.50 V, Unbuffered with ECC Dual In-Line Memory Module (UDIMM)
|
715269-001
|
|
c) 2GB, 1600 MHz, PC3L-12800E-11, DDR3, single-rank x8, 1.35 V, unbuffered with ECC dual in-line memory module (UDIMM)
|
715279-001
|
|
d) 4GB, 1600 MHz, PC3-12800R-11, DDR3, Single-Rank x4, 1.50 V, registered dual in-line memory module (DIMM)
|
664689-001
|
|
e) 4GB, 1333 MHz, PC3L-10600R-9, DDR3, single-rank x4, 1.35 V, registered dual in-line memory module (RDIMM)
|
664688-001
|
|
f) 4GB, 1866 MHz, PC3-14900E-13, DDR3, Single-Rank x8, 1.50 V, Unbuffered with ECC Dual In-Line Memory Module (UDIMM)
|
715270-001
|
|
g) 4GB, 1333 MHz, PC3L-10600E-9, DDR3, dual-rank x8, 1.35 V, unbuffered with ECC dual in-line memory module (UDIMM)
|
664695-001
|
|
h) 4GB, 1866 MHz, PC3-14900R-13, DDR3, dual-rank x4, 1.50 V, registered dual in-line memory module (RDIMM)
|
715272-001
|
|
i) 4GB, 1600 MHz, PC3L-12800E-11, DDR3, dual-rank x8, 1.35 V, unbuffered with ECC dual in-line memory module (UDIMM)
|
715280-001
|
|
j) 4GB, 1600 MHz, PC3L-12800R-11, DDR3, single-rank x4, 1.35 V, registered dual in-line memory module (RDIMM)
|
715282-001
|
|
k) 8GB, 1600 MHz, PC3-12800R-11, DDR3, single-rank x4, 1.50 V, registered dual in-line memory module (DIMM)
|
664691-001
|
|
l) 8GB, 1333 MHz, PC3L-10600R-9, DDR3, dual-rank x4, 1.35 V, registered dual in-line memory module (RDIMM)
|
664690-001
|
|
m) 8GB, 1333 MHz, PC3L-10600E-9, DDR3, dual-rank x8, 1.35 V, unbuffered with ECC dual in-line memory module (UDIMM)
|
664696-001
|
|
n) 8GB, 1866 MHz, PC3-14900E-13, DDR3, Dual-Rank x8, 1.50 V, Unbuffered with ECC Dual In-Line Memory Module (UDIMM)
|
715271-001
|
|
o) 8GB, 1866 MHz, PC3-14900R-13, DDR3, dual-rank x4, 1.50 V, registered dual in-line memory module (RDIMM)
|
715273-001
|
|
p) 8GB, 1600 MHz, PC3L-12800E-11, DDR3, Dual-Rank x8, 1.35 V, Unbuffered with ECC Dual In-Line Memory Module (UDIMM)
|
715281-001
|
|
q) 8GB, 1600 MHz, PC3L-12800R-11, DDR3, dual-rank x4, 1.35 V, registered dual in-line memory module (RDIMM)
|
715283-001
|
|
r) 8GB dual in-line memory module (DIMM), PC3L-12800R-11, 1Rx4
|
735302-001
|
|
s) 8GB, 1866 MHz, PC3-14900R-13, DDR3, quad-rank x4, 1.50 V, registered dual in-line memory module (DIMM)
|
735303-001
|
|
t) 16GB, 1600 MHz, PC3-12800R-11, DDR3, dual-rank x4, 1.50 V, registered dual in-line memory module (DIMM)
|
684031-001
|
|
u) 16GB, 1333 MHz, PC3L-10600R-9, DDR3, dual-rank x4, 1.35 V, registered dual in-line memory module (RDIMM)
|
664692-001
|
|
v) 16GB, 1866 MHz, PC3-14900R-13, DDR3, dual-rank x4, 1.50 V, registered dual in-line memory module (RDIMM)
|
715274-001
|
|
w) 16GB dual in-line memory module (DIMM), PC3L-12800R-11, 1Gx4
|
715284-001
|
|
x) 16GB, 1333 MHz, PC3-10600H-9, DDR3, Dual-Rank x4, 1.50 V, HyperCloud Dual In-Line Memory Module (HDIMM)
|
684032-001
|
|
y) 24GB, 1333 MHz, PC3L-10600R-9, DDR3, Three-Rank x4, 1.35 V, Registered Dual In-Line Memory Module (RDIMM)
|
718689-001
|
|
z) 32GB, 1333 MHz, PC3L-10600L-9, DDR3, Quad-Rank x4, 1.35 V, Load Reduced Dual In-Line Memory Module (LRDIMM)
|
664693-001
|
|
32
|
Processors:
2
|
|
a) Intel Xeon E5-2603 Quad-Core 64-bit
processor - 1.80 GHz (Sandy Bridge-EP, 10MB Level-3 cache, Intel
QuickPath interconnect (QPI) speed 6.4 GT/s, 80 W thermal design power
(TDP), FCLGA 2011-pin socket)
|
670533-001
|
|
b) Intel Xeon E5-2603 v2 Quad-Core 64-bit
processor - 1.80 GHz (Ivy Bridge-EP, 10MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 6.4 GT/s, 80 W thermal design power (TDP),
socket FCLGA 2011)
|
730243-001
|
|
c) Intel Xeon E5-2609 Quad-Core 64-bit
processor - 2.50 GHz (Sandy Bridge-EP, 10MB Level-3 cache, Intel
QuickPath interconnect (QPI) speed 6.4 GT/s, 80 W thermal design power
(TDP), FCLGA 2011-pin socket)
|
670530-001
|
|
d) Intel Xeon E5-2609 v2 Quad-Core 64-bit
processor - 2.50 GHz (Ivy Bridge-EP, 10MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 6.4 GT/s, 80 W thermal design power (TDP),
socket FCLGA 2011)
|
730242-001
|
|
e) Intel Xeon E5-2620 Six-Core 64-bit processor
- 2.00 GHz (Sandy Bridge-EP, 15MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 7.2 GT/s, 95 W thermal design power (TDP),
FCLGA 2011-pin socket)
|
670529-001
|
|
f) Intel Xeon E5-2620 v2 Six-Core 64-bit
processor - 2.10 GHz (Ivy Bridge-EP, 15MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 7.2 GT/s, 80 W thermal design power (TDP),
socket FCLGA 2011)
|
730241-001
|
|
g) Intel Xeon E5-2630L Six-Core 64-bit
low-power processor - 2.00 GHz (Sandy Bridge-EP, 15MB Level-3 cache,
Intel QuickPath interconnect (QPI) speed 8.0 GT/s, 60 W thermal design
power (TDP), FCLGA 2011-pin socket)
|
670535-001
|
|
h) Intel Xeon E5-2630L v2 Six-Core 64-bit
low-power processor - 2.40 GHz (Ivy Bridge-EP, 15MB Level-3 cache, Intel
QuickPath interconnect (QPI) speed 7.2 GT/s, 60 W thermal design power
(TDP), socket FCLGA 2011)
|
730244-001
|
|
i) Intel Xeon E5-2630 Six-Core 64-bit processor
- 2.30 GHz (Sandy Bridge-EP, 15MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 7.2 GT/s, 95 W thermal design power (TDP),
FCLGA 2011-pin socket)
|
670528-001
|
|
j) Intel Xeon E5-2630 v2 Six-Core 64-bit
processor - 2.60 GHz (Ivy Bridge-EP, 15MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 7.2 GT/s, 80 W thermal design power (TDP),
socket FCLGA 2011)
|
730240-001
|
|
k) Intel Xeon E5-2637 Dual-Core 64-bit
processor - 3.00 GHz (Sandy Bridge-EP, 5MB Level-3 cache, Intel
QuickPath Interconnect (QPI) speed 8.0 GT/s, 80 W thermal design power
(TDP), FCLGA 2011-pin socket)
|
670539-001
|
|
l) Intel Xeon E5-2637 v2 Quad-Core 64-bit
processor - 3.5 GHz (Ivy Bridge-EP, 15MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 130 W thermal design power (TDP),
socket FCLGA 2011)
|
730249-001
|
|
m) Intel Xeon E5-2640 Six-Core 64-bit processor
- 2.50 GHz (Sandy Bridge-EP, 15MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 7.2 GT/s, 95 W thermal design power (TDP),
FCLGA 2011-pin socket)
|
670527-001
|
|
n) Intel Xeon E5-2640 v2 Eight-Core 64-bit
processor - 2.00 GHz (Ivy Bridge-EP, 20MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 7.2 GT/s, 95 W thermal design power (TDP),
socket FCLGA 2011)
|
730239-001
|
|
o) Intel Xeon E5-2643 Quad-Core 64-bit
processor - 3.30 GHz (Sandy Bridge-EP, 10MB Level-3 cache, Intel
QuickPath interconnect (QPI) speed 8.0 GT/s, 130 W thermal design power
(TDP), socket FCLGA 2011)
|
670538-001
|
|
p) Intel Xeon E5-2643 v2 Six-Core 64-bit
processor - 3.50 GHz (Ivy Bridge-EP, 25MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 130 W thermal design power (TDP),
socket FCLGA 2011)
|
730248-001
|
|
q) Intel Xeon E5-2648L Eight-Core 64-bit
low-power processor - 1.80 GHz (Sandy Bridge-EP, 20MB Level-3 cache,
Intel QuickPath Interconnect (QPI) speed 8.0 GT/s, 70 W Thermal Design
Power (TDP), FCLGA 2011 socket)
|
672335-001
|
|
r) Intel Xeon E5-2650L Eight-Core 64-bit
low-power processor - 1.80 GHz (Sandy Bridge-EP, 20MB Level-3 cache,
Intel QuickPath interconnect (QPI) speed 8.0 GT/s, 70 W thermal design
power (TDP), FCLGA 2011-pin socket)
|
670534-001
|
|
s) Intel Xeon E5-2650L v2 Ten-Core 64-bit
low-power processor - 1.70 GHz (Ivy Bridge-EP, 25MB Level-3 cache, Intel
QuickPath interconnect (QPI) speed 8.0 GT/s, 70 W thermal design power
(TDP), socket FCLGA 2011)
|
730250-001
|
|
t) Intel Xeon E5-2650 Eight-Core 64-bit
processor - 2.00 GHz (Sandy Bridge-EP, 20MB Level-3 cache, Intel
QuickPath interconnect (QPI) speed 8.0 GT/s, 95 W thermal design power
(TDP), FCLGA 2011-pin socket)
|
670526-001
|
|
u) Intel Xeon E5-2650 v2 Eight-Core 64-bit
processor - 2.60 GHz (Ivy Bridge-EP, 20MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 95 W thermal design power (TDP),
socket FCLGA 2011)
|
730238-001
|
|
v) Intel Xeon E5-2658 Eight-Core 64-bit
processor - 2.10 GHz (Sandy Bridge-EP, 20MB Level-3 cache, Intel
QuickPath interconnect (QPI) speed 8.0 GT/s, 80 W thermal design power
(TDP), socket FCLGA 2011)
|
672336-001
|
|
w) Intel Xeon E5-2660 Eight-Core 64-bit
processor - 2.20 GHz (Sandy Bridge-EP, 20MB Level-3 cache, Intel
QuickPath interconnect (QPI) speed 8.0 GT/s, 95 W thermal design power
(TDP), FCLGA 2011-pin socket)
|
670525-001
|
|
x) Intel Xeon E5-2660 v2 Ten-Core 64-bit
processor - 2.20 GHz (Ivy Bridge-EP, 25MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 95 W thermal design power (TDP),
socket FCLGA 2011)
|
730237-001
|
|
y) Intel Xeon E5-2665 Eight-Core 64-bit
processor - 2.40 GHz (Sandy Bridge-EP, 20MB Level-3 cache, Intel
QuickPath interconnect (QPI) speed 8.0 GT/s, 115 W thermal design power
(TDP), FCLGA 2011-pin socket)
|
670524-001
|
|
z) Intel Xeon E5-2667 Six-Core 64-bit processor
- 2.90 GHz (Sandy Bridge-EP, 15MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 130 W thermal design power (TDP),
FCLGA 2011-pin socket)
|
670537-001
|
|
aa) Intel Xeon E5-2667 v2 Eight-Core 64-bit
processor - 3.00 GHz (Ivy Bridge-EP, 25MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 130 W thermal design power (TDP),
socket FCLGA 2011)
|
730247-001
|
|
bb) Intel Xeon E5-2670 Eight-Core 64-bit
processor - 2.60 GHz (Sandy Bridge-EP, 20MB Level-3 cache, Intel
QuickPath interconnect (QPI) speed 8.0 GT/s, 115 W thermal design power
(TDP), FCLGA 2011-pin socket)
|
670523-001
|
|
cc) Intel Xeon E5-2670 v2 Ten-Core 64-bit
processor - 2.50 GHz (Ivy Bridge-EP, 25MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 115 W thermal design power (TDP),
socket FCLGA 2011)
|
730236-001
|
|
dd) Intel Xeon E5-2680 Eight-Core 64-bit
processor - 2.70 GHz (Sandy Bridge-EP, 20MB Level-3 cache, Intel
QuickPath interconnect (QPI) speed 8.0 GT/s, 130 W thermal design power
(TDP), FCLGA 2011-pin socket)
|
670522-001
|
|
ee) Intel Xeon E5-2680 v2 Ten-Core 64-bit
processor - 2.80 GHz (Ivy Bridge-EP, 25MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 115 W thermal design power (TDP),
socket FCLGA 2011)
|
730235-001
|
|
ff) Intel Xeon E5-2690 Eight-Core 64-bit
processor - 2.90 GHz (Sandy Bridge-EP, 20MB Level-3 cache, Intel
QuickPath interconnect (QPI) speed 8.0 GT/s, 135 W thermal design power
(TDP), socket FCLGA 2011)
|
670521-001
|
|
gg) Intel Xeon E5-2690 v2 Ten-Core 64-bit
processor - 3.00 GHz (Ivy Bridge-EP, 25MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 130 W thermal design power (TDP),
FCLGA 2011 socket)
|
730234-001
|
|
hh) Intel Xeon E5-2695 v2 Twelve-Core 64-bit
processor - 2.40 GHz (Ivy Bridge-EP, 30MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 115 W thermal design power (TDP),
socket FCLGA 2011)
|
730246-001
|
|
ii) Intel Xeon E5-2697 v2 Twelve-Core 64-bit
processor - 2.70 GHz (Ivy Bridge-EP, 30MB Level-3 cache, Intel QuickPath
interconnect (QPI) speed 8.0 GT/s, 130 W thermal design power (TDP),
socket FCLGA 2011)
|
730245-001
|
|
33
|
Hot-plug SATA:
|
|
500GB hot-plug SATA hard disk drive - 7,200
RPM, 6Gb/sec transfer rate, 3.5-inch large form factor (LFF), Midline,
SmartDrive Carrier (SC) - Not for use in MSA products
|
658103-001
|
|
1TB hot-plug SATA hard disk drive - 7,200 RPM,
6Gb/sec transfer rate, 3.5-inch large form factor (LFF), Midline,
SmartDrive Carrier (SC) - Not for use in MSA products
|
657739-001
|
|
2TB hot-plug SATA hard disk drive - 7,200 RPM,
6Gb/sec transfer rate, 3.5-inch large form factor (LFF), Midline,
SmartDrive Carrier (SC) - Not for use in MSA products
|
658102-001
|
|
3TB hot-plug SATA hard disk drive - 7,200 RPM,
6Gb/sec transfer rate, 3.5-inch large form factor (LFF), Midline,
SmartDrive Carrier (SC) - Not for use in MSA products
|
628182-001
|
|
500GB hot-plug SATA hard disk drive - 7,200
RPM, 6Gb/sec transfer rate, 2.5-inch small form factor (SFF), Midline,
SmartDrive Carrier (SC)
|
656107-001
|
|
1TB hot-plug SATA hard disk drive - 7,200 RPM,
6Gb/sec transfer rate, 2.5-inch small form factor (SFF), Midline,
SmartDrive Carrier (SC) - Not for use in MSA products
|
656108-001
|
|
Hot-plug SAS:
1
|
||
34
|
||
2TB hot-plug dual-port SAS hard disk drive -
7,200 RPM, 6Gb/sec transfer rate, 3.5-inch large form factor (LFF),
Midline, SmartDrive Carrier (SC) - Not for use in MSA products
|
653948-001
|
|
3TB hot-plug dual-port SAS hard disk drive -
7,200 RPM, 6Gb/sec transfer rate, 3.5-inch large form factor (LFF),
Midline, SmartDrive Carrier (SC) - Not for use in MSA products
|
653959-001
|
|
300GB hot-plug dual-port SAS hard disk drive -
10,000 RPM, 6Gb/sec transfer rate, 2.5-inch small form factor (SFF),
Enterprise, SmartDrive Carrier (SC) - Not for use in MSA products
|
653955-001
|
|
450GB hot-plug dual-port SAS hard disk drive -
10,000 RPM, 6Gb/sec transfer rate, 2.5-inch small form factor (SFF),
Enterprise, SmartDrive Carrier (SC) - Not for use in MSA products
|
653956-001
|
|
600GB hot-plug dual-port SAS hard disk drive -
10,000 RPM, 6Gb/sec transfer rate, 2.5-inch small form factor (SFF),
Enterprise, SmartDrive Carrier (SC) - Not for use in MSA products
|
653957-001
|
|
900GB hot-plug dual-port SAS hard disk drive -
10,000 RPM, 6Gb/sec transfer rate, 2.5-inch small form factor (SFF),
Enterprise, SmartDrive Carrier (SC) - Not for use in MSA products
|
653971-001
|
|
72GB hot-plug dual-port SAS hard disk drive -
15,000 RPM, 6Gb/sec transfer rate, 2.5-inch small form factor (SFF),
Enterprise, SmartDrive Carrier (SC) - Not for use in MSA products
|
653949-001
|
|
146GB hot-plug dual-port SAS hard disk drive -
15,000 RPM, 6Gb/sec transfer rate, 2.5-inch small form factor (SFF),
Enterprise, SmartDrive Carrier (SC) - Not for use in MSA products
|
653950-001
|
|
300GB hot-plug dual-port SAS hard disk drive -
15,000 RPM, 6Gb/sec transfer rate, 2.5-inch small form factor (SFF),
Enterprise, SmartDrive Carrier (SC) - Not for use in MSA products
|
653960-001
|
|
450GB hot-plug dual-port SAS hard disk drive -
15,000 RPM, 6Gb/sec transfer rate, 3.5-inch large form factor (LFF),
Enterprise, SmartDrive Carrier (SC) - Not for use in MSA products
|
653951-001
|
|
600GB SAS hard disk drive - 15,000 RPM, 6Gb per
second transfer rate, 3.5-inch large form factor (LFF), Enterprise,
SmartDrive carrier (SC), hot-plug, dual-port (DP)
|
653952-001
|
|
500GB hot-plug dual-port SAS hard disk drive -
7,200 RPM, 6Gb/sec transfer rate, 2.5-inch small form factor (SFF),
Midline, SmartDrive Carrier (SC) - Not for use in MSA products
|
653953-001
|
|
1TB hot-plug dual-port SAS hard disk drive -
7,200 RPM, 6Gb/sec transfer rate, 2.5-inch small form factor (SFF),
Midline, SmartDrive Carrier (SC) - Not for use in MSA products
|
653954-001
|
|
1TB hot-plug dual-port SAS hard disk drive -
7,200 RPM, 6Gb/sec transfer rate, 3.5-inch large form factor (LFF),
Midline, SmartDrive Carrier (SC) - Not for use in MSA products
|
653947-001
|
|
35
|
Hot-plug solid state SATA:
1
|
|
100GB hot-plug Solid State Drive (SSD) - SATA
interface, 3Gb/sec transfer rate, 2.5-inch small form factor (SFF),
Multi-Level Cell (MLC), SmartDrive Carrier (SC)
|
653965-001
|
|
200GB hot-plug Solid State Drive (SSD) - SATA
interface, 3Gb/sec transfer rate, 2.5-inch small form factor (SFF),
Multi-Level Cell (MLC), SmartDrive Carrier (SC)
|
653966-001
|
|
400GB hot-plug Solid State Drive (SSD) - SATA
interface, 3Gb/sec transfer rate, 2.5-inch small form factor (SFF),
Multi-Level Cell (MLC), SmartDrive Carrier (SC)
|
653967-001
|
|
100GB hot-plug Solid State Drive (SSD) - SATA
interface, 3Gb/sec transfer rate, 3.5-inch large form factor (LFF),
Multi-Level Cell (MLC), Enterprise Mainstream, SmartDrive Carrier (SC)
|
653968-001
|
|
200GB hot-plug Solid State Drive (SSD) - SATA
interface, 3Gb/sec transfer rate, 3.5-inch large form factor (LFF),
Multi-Level Cell (MLC), Enterprise Mainstream, SmartDrive Carrier (SC)
|
653969-001
|
|
400GB hot-plug Solid State Drive (SSD) - SATA
interface, 3Gb/sec transfer rate, 3.5-inch large form factor (LFF),
Multi-Level Cell (MLC), Enterprise Mainstream, SmartDrive Carrier (SC)
|
653970-001
|
|
36
|
Hot-plug solid state SAS:
1
|
|
200GB hot-plug Solid State Drive (SSD) - SAS
interface, 6Gb/sec transfer rate, 2.5-inch small form factor (SFF),
Single-Level Cell (SLC), SmartDrive Carrier (SC)
|
653961-001
|
|
400GB hot-plug Solid State Drive (SSD) - SAS
interface, 6Gb/sec transfer rate, 2.5-inch small form factor (SFF),
Single-Level Cell (SLC), SmartDrive Carrier (SC)
|
653962-001
|
|
400GB hot-plug Solid State Drive (SSD) - SAS
interface, 6Gb/sec transfer rate, 2.5-inch small form factor (SFF),
Multi-Level Cell (MLC), SmartDrive Carrier (SC)
|
653963-001
|
|
800GB hot-plug Solid State Drive (SSD) - SAS
interface, 6Gb/sec transfer rate, 2.5-inch small form factor (SFF),
Multi-Level Cell (MLC), SmartDrive Carrier (SC)
|
653964-001
|
|
37
|
Optical disk drive (ODD) module cage - Includes
the front panel grill and optical drive bay - For 8-bay small form
factor (SFF) drive model servers - Mounts on the left side of the
chassis
|
675601-001
|
38
|
Slimline 8x/24x DVD-ROM optical drive (Jack Black Color) - SATA interface, 12.7 mm slim form factor
|
652294-001
|
39
|
Slimline 8x DVD+R/RW optical drive (Jack Black Color) - SATA interface, 12.7 mm slim form factor 1
|
652295-001
|
40
|
Optical drive bracket - For 9.5mm high optical
drives - Mounts to the rear of the optical drive and is used to secure
the drive in the drive bay
|
532475-001
|
41
|
Ribbon Mini-SAS storage cable - For the 8-bay
Large Form Factor (LFF) server models - Connects between the hard drive
connector backplane board and the system I/O board 1
|
675609-001
|
42
|
Ribbon Mini-SAS storage cable - For the 8-bay
or 16-bay Small Form Factor (SFF) server models - Connects between the
hard drive connector backplane board and the system I/O board1
|
675610-001
|
43
|
Miscellaneous cable kit contains: 25 SFF Mini-SAS SR cable, 12 LFF Mini-SAS SR cable and 12 LFF/25 SFF power cable1
|
725768-001
|
44
|
Ribbon mini-SAS storage cable - For 8-bay or
16-bay small form factor (SFF) server models - Connects between the hard
drive connector backplane board and a PCIe SAS controller board
(straight connectors on both ends) 1
|
675611-001
|
45
|
8 LFF drive cage data cable1
|
733716-001
|
46
|
12 LFF drive cage data cable1
|
733717-001
|
47
|
Mini-SAS drive cage data cable - for use with 25 disk option1
|
733718-001
|
48
|
6G SAS P430/830 Secondary Cable Kit1
|
733719-001
|
49
|
Power cable - For 8-bay or 12-bay Large Form
Factor (LFF) server models - Connects between the hard drive backplane
board and the system I/O board1
|
675612-001
|
50
|
Power cable - For 8-bay or 16-bay small form
factor (SFF) server models - Connects between the hard drive backplane
board and the system input-output (I/O) board1
|
675613-001
|
51
|
Slimline optical drive SATA cable, 440mm (17.3
inches) long - Connects between the rear of the optical drive and the
system input-output (I/O) board1
|
675614-001
|
52
|
Mini-SAS cable - 36-position straight connector to straight connector, 0.93 m (37 inches) long1
|
681908-001
|
53
|
Battery for real-time clock (RTC) - 3.0 V, 220 mAh, lithium coin cell, 20 mm diameter, 3.2 mm height (CR2032)1
|
319603-001
|
54
|
Standard efficiency heatsink
|
662522-001
|
55
|
FBWC cache module:
|
|
512MB flash backed write cache (FBWC) memory
module, 40-bit wide - Does not include the controller board or capacitor
module - For use with the P222 Smart Array controller
|
633540-001
|
|
1GB flash backed write cache (FBWC) memory
module, 72-bit wide - Does not include the controller board or capacitor
module - For use with the P420 and P421 Smart Array controllers1
|
633542-001
|
|
2GB flash backed write cache (FBWC) memory
module, 72-bit wide - Does not include the controller board or capacitor
module - For use with the P420, P421, P430, P431, and 822 Smart Array
controllers1
|
633543-001
|
|
56
|
FBWC Capacitor pack with 914 mm (36 inches)
long cable - Provides back up power to the flash-based write cache
(FBWC) memory module for up to 80 seconds in the event of a system power
failure - For use with Smart Array controllers
|
660093-001
|
57
|
Graphics
|
|
PCI board 2 slot x16x8
|
755741-001
|
|
Graphics cable
|
755742-001
|
|
NOTE: 1: Not shown in the above figure.